diff options
| author | Tim Keller <tjk@tjkeller.xyz> | 2026-09-02 21:01:46 -0500 |
|---|---|---|
| committer | Tim Keller <tjk@tjkeller.xyz> | 2026-09-02 21:01:46 -0500 |
| commit | e88a880435ebdda6e50bf16a493abb85b4e80d15 (patch) | |
| tree | cc59b2810868bcc90bb2772380945fc024f7f5ee /README.md | |
| parent | a74c2877571afbfd04584b8821c754e9050b9e72 (diff) | |
| download | telemetry-flake-flake-modules.tar.xz telemetry-flake-flake-modules.zip | |
add NVMe support, and give the self-test collector the device listHEADmasterflake-modules
Two configurations the modules claimed to support and did not.
NVMe drives had no per-drive section. smartctl:bus routes a drive by metric
presence -- ATA attribute table, or SCSI grown defect list -- and NVMe emits
neither, confirmed against a live smartctl_exporter 0.14.0 on real hardware.
With no bus label the smartctl:row join dropped them, so they appeared in Fleet
Overview and All Drives but could not be opened. Adds an nvme arm keyed on
smartctl_device_percentage_used, verdict rules over the SMART/Health
Information log, and a third repeating section.
The verdict is BAD on a critical warning, media errors, or available spare
below the drive's own threshold, and CAUTION at 90% of rated endurance.
num_err_log_entries is deliberately not in it: the NVMe drive in this machine
is healthy and sits at 2200, because it counts every command that ever
returned an error.
smart.devices reached the exporter but not the self-test collector, which
always ran its own `smartctl --scan` -- exactly what cannot see drives behind a
RAID controller, which is the only reason to set the option. The collector now
takes the same PATH[;TYPE] syntax and passes -d through.
That means it also has to reproduce the exporter's device label, which is not
the basename: /dev/bus/0 as megaraid,1 is bus_0_megaraid_1. Ported
buildDeviceLabel with its /dev/disk/by-{id,path}/ prefix stripping and the
comma rule, and the scan-time scsi -> auto fallback. Getting this wrong fails
silently -- every join in rules/smartctl.yml simply misses.
Verified: promtool; a Prometheus fixture covering all three transports plus a
megaraid-labelled device, asserting bus and verdict per drive and resolving
$ata_device/$sas_device/$nvme_device the way Grafana does; the grid layout;
the ExecStart with and without smart.devices; and the collector against this
machine's NVMe drive.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JKczN1f66kmLxNBLX37voQ
Diffstat (limited to 'README.md')
| -rw-r--r-- | README.md | 10 |
1 files changed, 5 insertions, 5 deletions
@@ -18,8 +18,8 @@ What *has* been checked: - every dashboard query executed against a real Prometheus fed fixture data - `promtool` over the recording rules and the generated scrape config - `nix flake check`: both modules evaluate, and both dashboard generators run -- the collectors run against mock `smartctl`/`zpool`/`zfs`, and partially against real - hardware +- the collectors run against mock `smartctl`/`zpool`/`zfs`, and against a real NVMe drive +- the NVMe metric names the rules depend on, checked against a live `smartctl_exporter` What has **not**: @@ -156,7 +156,7 @@ host and the whole page swaps to it. | dashboard | picker(s) | |---|---| -| Drive Health | **Host** → SATA drive / SAS drive | +| Drive Health | **Host** → SATA drive / SAS drive / NVMe drive | | ZFS Pools | **Host** → Pool | | Node Exporter Full | Job → Nodename → Instance | | Smartctl Exporter | Node | @@ -233,8 +233,8 @@ Shipped in `rules/alerts.yml`, loaded unless you set `alerts.defaultRules = fals | | condition | severity | |---|---|---| -| `DriveFailing` | SMART self-assessment failed, an attribute is below its threshold, or uncorrectable errors | critical | -| `DriveCaution` | reallocated/pending sectors, or a non-empty SAS grown defect list | warning | +| `DriveFailing` | SMART self-assessment failed, an attribute is below its threshold, uncorrectable errors, or an NVMe critical warning | critical | +| `DriveCaution` | reallocated/pending sectors, a non-empty SAS grown defect list, or 90%+ NVMe endurance used | warning | | `SelfTestFailed` | last short or extended self-test did not pass | critical | | `DriveOverheating` | above 55 °C for 30 minutes | warning | | `PoolNotOnline` | pool is DEGRADED, FAULTED, … | critical | |